Starter pack Tramex SP-F2170-B – ASTM F2170 in-situ relative humidity test (3 Hygro-i2 probes, cable, salt, 12 liners)
This product is priced individually. Fill in the form to receive a dedicated quote.
Informazioni di prodotto e di utilizzo
Tramex SP-F2170-B starter pack for in-situ relative humidity testing in concrete to ASTM F2170 with the CMEX5, MEX5 and DL-RHTX: 3 Hygro-i2® probes, interface cable, calibration salt check and 12 hole liners.
Description
SP-F2170-B starter pack for carrying out in-situ relative humidity testing in concrete to ASTM F2170 with the CMEX5, MEX5 and Feedback Datalogger DL-RHTX.
Key features
- 3 reusable Hygro-i2® probes
- Interface cable and calibration salt check
- 12 hole liners, 19 mm
- For ASTM F2170 tests
Typical applications
- In-situ relative humidity tests in screeds to ASTM F2170
Supplied with
3 reusable Hygro-i2® probes · 1 interface cable · 1 calibration salt check · 12 hole liners, 19 mm
Compatible with
- Tramex MEX5
- Tramex CMEX5
- DL-RHTX
Price and availability
The price for this accessory is available on request: contact us for a quote, telling us which instrument it is intended for.
Selection guide
Tramex SP-F2170-B starter pack for in-situ relative humidity testing in concrete to ASTM F2170 with CMEX5, MEX5 and DL-RHTX: 3 Hygro-i2® probes, interface cable, calibration salt check and 12 hole liners.
Hygro-i2 probes and their accessories work only with Tramex MEX5, Tramex CMEX5, DL-RHTX. To get started with the ASTM F2170 test, choose the SP-F2170-B starter pack (3 probes, cable, calibration salt check, 12 hole liners); if you already have the instrument and cable, add HIPP probes and RHHL hole liners (Ø 19 mm, ASTM-compliant) or RHHLSR liners (Ø 16 mm, for non-ASTM tests); the HI-EX tool and HI-ACC toolbox make insertion and removal easier; SAL75 salts check the calibration of the probes.
If in doubt, contact us: our technical support team will recommend the right accessory for your instrument and application.
Integration and programming
The hole in the screed is drilled to the depth required by the standard (40% of the thickness for slabs drying from one side, 20% for slabs drying from both sides), cleaned, and fitted with the liner and cap; after acclimatisation, the Hygro-i2 probe is inserted; the reading is taken by connecting the RHIE2B cable to the instrument. With the Tramex Meters app you record position, date and values for the test report.
Calibration and repair
Hygro-i2 probes are reusable: check their calibration with the SAL75 calibration salt check (75% RH reference environment) before each test campaign and at least once a year. Liners and caps are consumables.
Service: RODER S.r.l. – INNOVACHECK division, Tramex distributor for Italy, will assist you with selection, use and sending instruments to Tramex for certified calibration and repairs. Contact us, stating the model and serial number of your instrument.