Tool box Tramex HI-ACC – for ASTM F2170 tests with Hygro-i2 probes
- SKU: HI-ACC
- VENDOR: Tramex
Couldn't load pickup availability
Safe and secure payments:
Informazioni di prodotto e di utilizzo
Tramex HI-ACC tool box with the tools for in-situ ASTM F2170 relative humidity testing with Hygro-i2® probes.
Description
The Hygro-i2® HI-ACC accessory box contains the tools required for in-situ ASTM F2170 relative humidity testing.
Key features
- Tools for ASTM F2170 testing
- Hygro-i2® insertion and extraction tool
- Code HI-ACC
Typical applications
- In-situ relative humidity tests in screeds to ASTM F2170
Supplied with
Ruler · Hygro-i2® insertion and extraction tool · Wire brush · Hole liner insertion tool · Shears · Key for changing the pins of the optional pin hygrometer
Compatible with
- Tramex MEX5
- Tramex CMEX5
- DL-RHTX
Selection guide
Tramex HI-ACC toolbox with the tools for ASTM F2170 in-situ relative humidity testing with Hygro-i2® probes.
Hygro-i2 probes and their accessories work only with Tramex MEX5, Tramex CMEX5, DL-RHTX. To get started with the ASTM F2170 test, choose the SP-F2170-B starter pack (3 probes, cable, calibration salt check, 12 hole liners); if you already have the instrument and cable, add HIPP probes and RHHL hole liners (Ø 19 mm, ASTM-compliant) or RHHLSR liners (Ø 16 mm, for non-ASTM tests); the HI-EX tool and HI-ACC toolbox make insertion and removal easier; SAL75 salts check the calibration of the probes.
If in doubt, contact us: our technical support team will recommend the right accessory for your instrument and application.
Integration and programming
The hole in the screed is drilled to the depth required by the standard (40% of the thickness for slabs drying from one side, 20% for slabs drying from both sides), cleaned, and fitted with the liner and cap; after acclimatisation, the Hygro-i2 probe is inserted; the reading is taken by connecting the RHIE2B cable to the instrument. With the Tramex Meters app you record position, date and values for the test report.
Calibration and repair
Hygro-i2 probes are reusable: check their calibration with the SAL75 calibration salt check (75% RH reference environment) before each test campaign and at least once a year. Liners and caps are consumables.
Service: RODER S.r.l. – INNOVACHECK division, Tramex distributor for Italy, will assist you with selection, use and sending instruments to Tramex for certified calibration and repairs. Contact us, stating the model and serial number of your instrument.