With the CMP probe, the CME5 or CMEX5 concrete moisture meter reads the moisture content within the body of the slab, to a depth of 100 mm, in a 19 mm hole: together with the non-destructive test of the first 20 mm it forms the Tramex Unified Test Method, with all readings expressed in %MC. No batteries, no calibration, reusable probes.
Compatible with
Tramex CME5, Tramex CMEX5. The probe does not work on its own: it requires an instrument from the CME range.
What it is for
The non-destructive test measures the surface layer of the slab; to find out how much moisture is in the body of the pour, a depth measurement is needed. The CMP probe is inserted in a hole drilled in advance with a 19 mm bit (the same diameter as RH tests to ASTM F2170), the CME meter is placed on the probe cradle and reads the moisture content in %MC to 100 mm. The advantage over other methods is that surface and depth are expressed in the same unit, without having to compare heterogeneous data. The probes are reusable, extendable and replaceable; no sleeves or batteries are needed.
How it works
The CME meter, pressed onto the probe cradle, generates a low-frequency alternating electric field between its own electrodes and the probe inserted in the hole; the current flowing through the field is inversely proportional to the impedance of the concrete, which depends on the water content. The instrument converts it into %MC on the concrete scale; for other cementitious materials the reference scale and the CM scales are used.
Technical data
| Principle | Electrical impedance between the meter electrodes and the probe in the hole |
|---|---|
| Measuring depth | Up to 100 mm |
| Hole required | 19 mm (3/4″) bit, no sleeve |
| Reading | % MC on the meter's concrete scale (gravimetric method); reference and CM scales for other substrates |
| Method | Tramex Unified Moisture Content Test: NDT of the first 20 mm + in situ |
| Power supply | None (uses the meter) |
| Calibration | Not required |
| Probes | Reusable, extendable, replaceable |
| Compatibility | CME5, CMEX5, CME4, CMEX2 |
| Limitations of use | Does not measure through conductive materials or wet surfaces |
| Code | CMP |
| Warranty | 1 year Tramex |
Documentation
| Documentation in English | |
| USER MANUAL “THE DETERMINATOR” | |
| QUICK GUIDE | |
Selection guide: CMP «The Determinator»
In-situ moisture probe for concrete, for use with Tramex CME5 or Tramex CMEX5: it measures moisture within the body of the slab down to a depth of 100 mm (not just at the surface like the non-invasive reading), with a quantitative comparison against the gravimetric method. Suitable for checking screeds before laying floor coverings and for disputes, as an alternative or complement to the Hygro-i2 probes (ASTM F2170) of the CMEX5. Also available in the Concrete Determinator kits.
If in doubt, contact us: our technical support team will recommend the right accessory for your instrument and your application.
Integration
Drill the slab with the specified bit, insert the probe and place the CME5/CMEX5 meter on the probe cradle: the reading is taken on the instrument's concrete scale, with no additional electronics. With the CMEX5 and the Tramex Meters app, values are recorded in the report.
Calibration and repair
The probe does not require its own calibration: the measuring chain is verified by checking the instrument on the CALCRH plate. Clean the probe after use and protect the contact surface from impact.