Hole liners Tramex RHHLSR – Ø 16 mm with plugs, for Hygro-i2 probes (not ASTM F2170)
This product is priced individually. Fill in the form to receive a dedicated quote.
Informazioni di prodotto e di utilizzo
Tramex RHHLSR 16 mm hole liners with plugs for Hygro-i2® probes, for in-situ relative humidity tests to BS 8201, 8203, 5325 (not for ASTM F2170); pack of 100.
Description
RHHLSR hole liners with plugs for Tramex Hygro-i2® relative humidity probes, for in-situ relative humidity testing of concrete floors and slabs to BS 8201, 8203 and 5325. Not suitable for ASTM F2170 testing. Pack of 100.
Key features
- For 16 mm holes
- For BS 8201, 8203, 5325 tests
- Not for ASTM F2170
- Pack of 100
Compatible with
- Tramex MEX5
- Tramex CMEX5
- DL-RHTX
Price and availability
The price for this accessory is available on request: contact us for a quote, telling us which instrument it is intended for.
Selection guide
Tramex RHHLSR 16 mm hole liners with caps for Hygro-i2® probes, for in-situ relative humidity tests to BS 8201, 8203, 5325 (not for ASTM F2170); pack of 100.
Hygro-i2 probes and their accessories work only with Tramex MEX5, Tramex CMEX5, DL-RHTX. To get started with the ASTM F2170 test, choose the SP-F2170-B starter pack (3 probes, cable, calibration salt check, 12 hole liners); if you already have the instrument and cable, add HIPP probes and RHHL hole liners (Ø 19 mm, ASTM-compliant) or RHHLSR liners (Ø 16 mm, for non-ASTM tests); the HI-EX tool and HI-ACC toolbox make insertion and removal easier; SAL75 salts check the calibration of the probes.
If in doubt, contact us: our technical support team will recommend the right accessory for your instrument and application.
Integration and programming
The hole in the screed is drilled to the depth required by the standard (40% of the thickness for slabs drying from one side, 20% for slabs drying from both sides), cleaned, and fitted with the liner and cap; after acclimatisation, the Hygro-i2 probe is inserted; the reading is taken by connecting the RHIE2B cable to the instrument. With the Tramex Meters app you record position, date and values for the test report.
Calibration and repair
Hygro-i2 probes are reusable: check their calibration with the SAL75 calibration salt check (75% RH reference environment) before each test campaign and at least once a year. Liners and caps are consumables.
Service: RODER S.r.l. – INNOVACHECK division, Tramex distributor for Italy, will assist you with selection, use and sending instruments to Tramex for certified calibration and repairs. Contact us, stating the model and serial number of your instrument.