Calibration check plate Tramex CALCRH – for CME5 and CMEX5
- SKU: CALCRH
- VENDOR: TRAMEX
Couldn't load pickup availability
Safe and secure payments:
Informazioni di prodotto e di utilizzo
Calibration reference for concrete moisture meters: place the instrument on the plate, press the spring-loaded base down fully and compare the reading with the reference value. For the CME5, CMEX5 and the earlier CME4 and CMEX2.
Compatible with
What it is for
Before testing a slab, the CALCRH plate makes it possible to document that the instrument is in control: a check lasting a few seconds that goes into the test report and satisfies ISO 9001 procedures. If the reading is outside tolerance, the instrument must be sent for calibration. It does not replace the annual certified calibration.
How to use it
Switch the instrument on at the indicated scale, place it on the plate pressing the spring-loaded base down fully, read and compare with the reference. No batteries, no maintenance.
Key features
| Compatibility | CME5, CMEX5, CME4, CMEX2 |
|---|---|
| Function | Checking the non-destructive scale reading against a known reference |
| Power supply | None |
| Code | CALCRH |
| Included in | AP-CM accessory kit |
Selection guide: CALCRH
Calibration check plate for CME5 and CMEX5 concrete moisture meters (and for the earlier CME4 and CMEX2). It is the reference for periodic calibration checks on site: place the instrument on the plate and in a few seconds you can verify that the reading is within tolerance. Compatible with Tramex CME5, Tramex CMEX5. Recommended for those working under ISO 9001 or signing survey reports; it is also included in the AP accessory sets.
If in doubt, contact us: our technical support team will recommend the right accessory for your instrument and your application.
Integration
No configuration needed: switch the instrument on, select the scale shown on the box, place the instrument on it and compare the reading with the reference value. With the Tramex Meters app, the check can be recorded with date and time in the report.
Calibration and repair
The box has no batteries or wearing parts and does not require calibration; keep it in its pouch, away from moisture and heat sources. If the instrument's reading on the box is out of tolerance, the instrument must be sent for calibration: the box does not replace the annual certified calibration.
Service: RODER S.r.l. – INNOVACHECK division, Tramex distributor for Italy, will help you with selection, use and sending instruments to Tramex for certified calibration and repairs. Contact us stating the model and serial number of your instrument.