Insulated hood Tramex Hygrohood RHIH – concrete surface relative humidity test (BS 8201/8203/5325)
- SKU: RHIH
- VENDOR: Tramex
Couldn't load pickup availability
Safe and secure payments:
Informazioni di prodotto e di utilizzo
Tramex Hygrohood (RHIH) insulated hood for testing the relative humidity of concrete with an external probe; can be used with the TREMS-Xtra for remote monitoring, as well as with the CMEX5 and Feedback Datalogger.
Description
The Tramex (Ireland) Hygrohood RHIH is an insulated hood for testing the relative humidity of concrete and cementitious structures using the insulated, waterproof hood method set out in BS 8201, BS 8203 and BS 5325. It is used with an external Tramex relative humidity probe and with a CMEX5 hygrometer, a Feedback Datalogger or the TREMS-Xtra remote monitoring system.
With the TREMS-Xtra, each Cloud Sensor can be connected to a hood on site and transmit relative humidity, temperature, dew point and humidity ratio via the Cloud Station, with remote monitoring of up to 200 sensors and hoods on the Tramex Cloud platform.
The hood is sealed with butyl tape onto the clean surface and the external probe is inserted into the hood. Dimensions 195 x 195 x 55 mm, ABS body.
Key features
- Insulated hood for relative humidity tests on concrete
- Compliant with BS 8201, 8203 and 5325
- For TREMS-Xtra, CMEX5 or Feedback Datalogger with external probe
- 195 x 195 x 55 mm, ABS body
Typical applications
- Remote monitoring of the relative humidity of concrete
- Checking screeds before floor laying
Compatible with
- Tramex CMEX5
- DL-RHTX
- TREMS-Xtra
Selection guide
Tramex Hygrohood (RHIH) insulated hood for testing the relative humidity of concrete with an external probe, usable with TREMS-Xtra for remote monitoring, as well as with CMEX5 and Feedback Datalogger.
The Hygrohood is used with an external Tramex relative humidity probe (e.g. RHP-SW-B) connected to Tramex CMEX5, DL-RHTX, TREMS-Xtra: this is the insulated hood method specified by BS 8201, 8203 and 5325 for screeds; HOODT butyl tape is used to seal the hood to the surface. For the in-situ test to ASTM F2170, use Hygro-i2 probes instead.
If in doubt, contact us: our technical support team will recommend the right accessory for your instrument and application.
Integration and programming
Clean the surface, seal the hood with HOODT tape, insert the probe into its housing and wait for the acclimatisation time required by the standard before reading relative humidity and temperature on the instrument or data logger.
Calibration and repair
The hood does not require calibration; periodically check the probe with the calibration salt check. Butyl tape is a consumable.
Service: RODER S.r.l. – INNOVACHECK division, Tramex distributor for Italy, will assist you with selection, use and sending instruments to Tramex for certified calibration and repairs. Contact us, stating the model and serial number of your instrument.