Dakota ZX5-DL ultrasonic thickness gauge with data logger – thickness and corrosion, dual element transducers
This product is priced individually. Fill in the form to receive a dedicated quote.
Informazioni di prodotto e di utilizzo
Dakota NDT ZX series ultrasonic thickness gauge for thickness and corrosion measurement with 1 to 10 MHz dual element transducers. Measures from 0.63 to 914.4 mm with 0.01 mm resolution, stores 10,000 readings and transfers them to a PC via USB-C.
Key features
- 1 to 10 MHz dual element transducers
- Measuring range from 0.63 to 914.4 mm
- Resolution 0.01 mm
- Memory for 10,000 readings, CSV files via USB-C
- Alarms, differential mode and fast scan
- Aluminium body, sealed keypad
- 5-year limited warranty
Description
The ZX5-DL is the ultrasonic thickness gauge with data memory in the Dakota NDT ZX series (Elcometer group), designed to withstand the harshest industrial conditions. It measures in pulse-echo mode with 1 to 10 MHz dual element transducers (transmit and receive) and replaces the previous ZX-5 DL.
The electronics are based on 120 MHz FPGA timing and a 150 V square wave pulser. Gain is adjustable from 40 to 52 dB in 3 dB steps (very low, low, medium, high, very high); zero can be set manually or automatically; the transducer diameter can be selected to improve linearity.
Measuring range from 0.63 to 914.4 mm, depending on the material and the transducer. Resolution 0.01 mm (0.001 inch), metric and imperial units. Sound velocity range from 305 to 18,542 m/s, repetition rate 200 Hz, display update 10 Hz.
Functions: fast scan at 100 Hz with minimum reading display; differential mode against a nominal value; high and low threshold alarms with audible and visual signalling; velocity measurement (VX) for nodularity checks.
4.5-digit LCD with 12.7 mm high digits, reading stability bar, adjustable backlight (off, on, automatic; three brightness levels). Sealed nine-key membrane keypad, resistant to water and petroleum products. Extruded aluminium body with sealed nickel-plated aluminium end caps.
32-megabit flash memory: 40 files of 250 readings, for 10,000 readings, downloadable as CSV files via USB-C without dedicated software. Optional RS232 or Bluetooth modules.
Powered by two AA batteries (1.5 V alkaline, 1.2 V NiCd or 1.5 V lithium): approximately 45 hours with alkaline and 23 hours with NiCd; automatic switch-off after 5 minutes; mains power via USB-C.
Dimensions 63.5 x 131.3 x 31.5 mm, weight 11 oz (approximately 310 g) with batteries, operating temperature from -30 to 75 °C. Quick-release LEMO connectors with locking. Factory calibration traceable to NIST and MIL-STD-45662A. Made in the USA, 5-year limited warranty.
Typical applications
- Measurement of corrosion and pitting
- Thickness of pipes and piping
- Thickness of tank walls
- Boiler thickness checks
- Glass thickness measurement
- Nodularity checks by sound velocity measurement (VX)
Technical data
| Product code | Z-304-0000 |
Supplied with
- ZX5-DL thickness gauge
- USB cable for data download
Not included: Transducers: not supplied, to be ordered separately
Compatible accessories
- A-302-6002 – ZX & PZX Gauge Series Instrument Case: Rubber Not
- T-104-1000 – Dual Element - Standard 2.25MHz 1/2" Potted Side
- T-102-2000 – Dual Element - Standard 5MHz 1/4" Potted Side
- X-000-0022 – Calibration Block: 5 Step; 2.5 - 12.5mm; 1018 Steel
- X-000-0021 – Calibration Block: 4 Step; 6.25 - 25mm; 1018 Steel
Documentation
Technical details on innovacheck.com
Price and availability
The price for this product is provided on request: contact us for a quote , stating quantity and application.
Selection guide: when to choose the ZX5-DL
The ZX5-DL is the thickness gauge in the ZX series for thickness and corrosion measurement with data logging: the same robustness as the ZX3, with the addition of reading memory, alarms and differential mode. Choose it if you need to document inspections and download the measurements to a PC.
Consider another model if: you do not need the data memory (ZX3); you need to measure through paint (ZX6-DL); you work on thin materials or plastics with a resolution of 0.001 mm (PZX1-DL).
Please note: the transducer is not included and must be chosen according to the application.
If in doubt, contact us with your application, measuring range and required accuracy: our technical support will recommend the right model and accessories.
Integration and programming
Connect the transducer, set the sound velocity of the material, perform the zero and read the thickness. Readings are saved in the internal memory and downloaded to a PC via USB as CSV files, ready for spreadsheets and inspection reports. From the keypad you can set gain, alarms, differential mode and fast scan.
Calibration and repair
In the field, verification is carried out on step calibration blocks: set the velocity of the material and check the reading on the known steps. Always use an ultrasonic couplant and replace the transducer when the contact surface is worn.
Service: RODER S.r.l. – INNOVACHECK division handles calibration with certificate, periodic verification and repair of Dakota NDT thickness gauges in Italy, in cooperation with the manufacturer. Contact us with the model and serial number.