Entry-level fixed-velocity Dakota NDT ultrasonic thickness gauge that requires no specific training: calibration is done by selecting the known velocity of the material. Measures in pulse-echo with dual-element transducers from 1 to 10 MHz, from 0.63 to 914.4 mm with 0.01 mm resolution.
Key features
- Easy to use: fixed-velocity calibration by selecting the known velocity of the material
- Pulse-Echo measurement with dual-element transducers 1 – 10 MHz
- 120 MHz FPGA timing and 150 V square-wave pulser
- Custom LCD display for low temperatures (-30 °C)
- Adjustable material velocity
- Automatic V-path correction (double path)
- 5-year limited warranty
Description
The ZX1 is the entry-level fixed-velocity ultrasonic thickness gauge from Dakota NDT (Elcometer group): it requires no specific training and calibration is performed simply by selecting a known sound velocity of the material. It is designed to withstand the harshest industrial conditions and replaces the previous ZX-1 model.
Measures in pulse-echo with dual-element transducers (transmit and receive) from 1 to 10 MHz. The electronics are based on 120 MHz FPGA timing and a 150 V square-wave pulser. The material velocity can be adjusted from the keypad.
Measuring range from 0.63 to 914.4 mm, depending on the material and the transducer. Resolution 0.01 mm (0.001 inch), metric and imperial units. Sound velocity range from 305 to 18,542 m/s, repetition rate 200 Hz, display update 10 Hz.
4.5-digit LCD with 12.7 mm tall digits, with fields for labels and values, reading stability bar, adjustable backlight (off, on, automatic; three brightness levels), working down to -30 °C. Sealed seven-key membrane keypad, resistant to water and petroleum products. Extruded aluminium body with sealed nickel-plated aluminium end caps.
Powered by two AA batteries (1.5 V alkaline, 1.2 V NiCd or 1.5 V lithium): about 45 hours with alkaline and 23 hours with NiCd; low-battery indicator and automatic shut-off when the charge no longer guarantees reliable measurements.
Dimensions 63.5 x 131.3 x 31.5 mm, weight 11 oz (about 310 g) with batteries, operating temperature from -30 to 75 °C. Locking quick-release LEMO connectors. Factory calibration traceable to NIST and MIL-STD-45662A. Made in the USA, 5-year limited warranty.
Technical data
| Measurement modes | Pulse-Echo (P-E) |
| Measuring range | 1.5 – 200 mm (0.059 – 8") in P-E (depends on material and transducer) – data from the Dakota product page |
| Resolution | 0.01 mm (0.001") |
| Velocity range | 305 – 18,542 m/s (0.0120 – 0.7300 in/µs); velocity adjustable from the keypad |
| Transducers | Dual-element, 1 – 10 MHz; locking quick-release LEMO connectors; 4 ft cable |
| Electronics | 120 MHz FPGA timing; 150 V square-wave pulser; PRF 200 Hz |
| Display | 7-segment LCD, 4.5 digits, digit height 0.5"; backlight on/off/auto, brightness Lo/Med/Hi; reading stability bar; 10 Hz update |
| Units | mm or inches |
| Power supply | 2 AA batteries (1.5 V alkaline, 1.2 V NiCad or 1.5 V lithium) |
| Battery life | approx. 45 h alkaline / 23 h NiCad; low-battery indicator; automatic shut-off when battery is insufficient |
| Operating temperature | -30 – +75 °C (-22 – 167 °F) |
| Housing | Extruded aluminium body with nickel-plated aluminium end caps (sealed gaskets); sealed membrane keypad resistant to water and petroleum products, 7 keys |
| Dimensions | 63.5 × 131.3 × 31.5 mm |
| Weight | 11 oz (312 g) with batteries |
| Certification / warranty | Factory calibration traceable to NIST and MIL-STD-45662A; 5-year limited warranty |
| Product code | Z-300-0000 |
Supplied with
ZX1 instrument · Ultrasonic couplant · Manual · Plastic carrying case · Calibration certificate · AA batteries · Transducer: NOT included – to be chosen and ordered separately from those listed on this page. dakotandt.com "ZX Series Corrosion Thickness Gauges".
Compatible transducers
- T-104-0000 – Standard dual-element transducer, 1 MHz, Ø 1/2", Potted connector, side exit
- T-102-1000 – Standard dual-element transducer, 2.25 MHz, Ø 1/4", Potted connector, side exit
- T-104-1000 – Standard dual-element transducer, 2.25 MHz, Ø 1/2", Potted connector, side exit
- T-101-2000 – Standard dual-element transducer, 5 MHz, Ø 3/16", Potted connector, side exit
- T-102-2000 – Standard dual-element transducer, 5 MHz, Ø 1/4", Potted connector, side exit
- T-104-2000 – Standard dual-element transducer, 5 MHz, Ø 1/2", Potted connector, side exit
- T-101-3700 – Hi-Damped (echo-echo / thru-paint) dual-element transducer, 7.5 MHz, Ø 3/16", Potted connector, side exit
- T-101-4000 – Standard dual-element transducer, 10 MHz, Ø 3/16", Potted connector, side exit
- T-102-4000 – Standard dual-element transducer, 10 MHz, Ø 1/4", Potted connector, side exit
- T-102-3300 – Extra Resolution (thin materials) dual-element transducer, 7.5 MHz, Ø 1/4", Potted connector, side exit
Compatible couplants
- GEL-ACC-STD – Yellow rust-inhibiting couplant gel, RCCM compliant. Standard temperature range 0 / 80 °C. 500 ml pack
- GEL-ACC-EXT – Blue anti-corrosion couplant gel, RCCM compliant. Extended temperature range -20 / 120 °C. 500 ml pack
- PST-ACC-UHT – Special ultrasonic coupling paste for very high temperatures +100 / 520 °C. Non-flammable and smoke-free. RCCM compliant. 200 g pack
Compatible calibration blocks
- X-000-0001 – 5-step calibration block 0.1"–0.5", 4340 steel
- X-000-0002 – 4-step calibration block 0.25"–1.0", 4340 steel
- X-000-0022 – 5-step calibration block 2.5–12.5 mm, 1018 steel
- X-000-0021 – 4-step calibration block 6.25–25 mm, 1018 steel
- X-000-0005 – Calibration block case
Compatible accessories / spare parts
- F-302-0001 – Nylon instrument case (ZX and PZX series)
- A-302-6002 – Rubber instrument case (ZX and PZX series)
- A-302-6003 – Plastic carrying case (ZX and PZX series)
- N-003-0330 – USB-C / USB-A data cable 0.9 m (V2.0 instruments)
- F-000-7001 – Spring-loaded bell probe holder (V-Block) – dual-element transducers, pipe inspection
Transducers are not included with the instrument and must be ordered separately.
Price and availability
Dakota NDT instruments are offered in a configuration (instrument + transducer + accessories) defined together with our technical support team: contact us for a quote stating the material, thicknesses and measuring conditions.
Selection guide: when to choose the ZX1
The ZX1 is the entry-level model of the ZX series: it measures the thickness of metals and other materials in pulse-echo mode with dual-element transducers, with fixed-velocity calibration (you select the known velocity of the material) and no specific training required. Same robust construction as the other ZX models.
Choose it if you carry out routine thickness checks on known materials, with a single operator and no need to record data.
Consider another model if: you need adjustable gain and minimum-value scanning (ZX3); you need to measure through paint or record readings (ZX6-DL); you need to measure material and coating together (CMX1-DL); you work on thin sections or plastics (PZX1-DL, PMX2-DL).
The probe is not included and must be chosen according to the application.
Contact us: our technical support will recommend the right instrument and probe for your application.
Integration and programming
The ZX1 is direct-reading, with no memory or data outputs: you connect the probe, set the material velocity, perform the zero and read the thickness. Automatic V-path correction for dual-element transducers. No programming.
If you need to record and download measurements, choose the model with data logger, the ZX6-DL.
Calibration and repair
The ZX1 is supplied with a factory calibration certificate (NIST, MIL-STD-45662A); verify in the field on the step calibration blocks with the material velocity set; always use an ultrasonic couplant.
Service: RODER S.r.l. – INNOVACHECK division handles calibration with certificate, periodic verification and repairs in Italy, in collaboration with Dakota NDT. Contact us with the model and serial number.