Digital benchtop cap torque tester Shimpo TNC series – ranges from 2 to 20 N·m
This product is priced individually. Fill in the form to receive a dedicated quote.
Informazioni di prodotto e di utilizzo
Digital benchtop torque tester Shimpo TNC-2 for opening and closing torque of caps, range 0.1–2 N·m (0.89–17.7 in·lbf), accuracy ±0.3% of reading, samples from 19.5 to 190 mm, USB and RS-232 outputs.
Models in the series
| TNC-2 | Digital benchtop torque tester Shimpo TNC-2 for opening and closing torque of caps, range 0.1–2 N·m (0.89–17.7 in·lbf), accuracy ±0.3% of reading, samples from 19.5 to 190 mm, USB and RS-232 outputs. |
| TNC-5 | Digital benchtop torque tester Shimpo TNC-5 for opening and closing torque of caps, range 0.25–5 N·m (2.2–44.3 in·lbf), accuracy ±0.3% of reading, samples from 19.5 to 190 mm, USB and RS-232 outputs. |
| TNC-10 | Digital benchtop torque tester Shimpo TNC-10 for opening and closing torque of caps, range 0.5–10 N·m (4.4–88.5 in·lbf), accuracy ±0.3% of reading, samples from 19.5 to 190 mm, USB and RS-232 outputs. |
| TNC-20 | Digital benchtop torque tester Shimpo TNC-20 for opening and closing torque of caps, range 1–20 N·m (8.9–177 in·lbf), accuracy ±0.3% of reading, samples from 19.5 to 190 mm, USB and RS-232 outputs. |
Description
The Shimpo TNC series digital cap torque tester measures opening and closing torque simply and quickly up to 20 N·m (14.8 ft·lb) on samples with a diameter of 19.5 to 190 mm. It is used in the medical and pharmaceutical sectors, in industrial quality control, in research and development and in many other torque measurement applications.
Operates from the internal rechargeable battery or the supplied power adapter. It has seven modes: Track (real-time reading), Peak, First Peak, Auto Peak, Auto First Peak, Double Peak and Preset with programmable tolerance thresholds for pass/fail testing. The backlit, reversible LCD display shows an analogue bar graph with the direction of rotation (clockwise/counter-clockwise) and result icons; a graph view of the whole test is also available.
Accuracy ±0.3% of reading from 5 to 100% of full scale, sampling rate 2000 Hz, overload 120% of full scale, 1000-reading memory, USB, RS-232 and NPN high/low limit outputs, free software for downloading and statistical analysis of data. Units N·cm, N·m, in·lb, ft·lb, kgf·cm (depending on range). Ni-MH battery 3.6 V 1600 mAh, battery life approx. 25 hours, universal USB charger 110–240 V AC. Operating temperature from -10 to 40 °C, humidity 20–80% RH. Dimensions 197 x 200 x 142 mm, weight 2.5 kg. CE marking, RoHS. 1-year warranty. Supplied with a factory calibration certificate with data.
Model TNC-2: range 0.1–2 N·m (0.89–17.7 in·lbf).
Typical applications
- Opening and closing torque of caps and closures
- Pharmaceutical, medical and food quality control
- Research and development
Supplied with
4 clamping posts, 30 mm · USB cable · AC adapter/battery charger · 2 fixing bolts · Rubber bench feet · Calibration certificate
Compatible accessories and spare parts
- FG-7CHRG – Battery charger for torque testers and force gauges Shimpo FG-7000, FG-3000, TNC, TTC
- FG-7USB – USB cable for torque testers and force gauges Shimpo FG-7000 series, FG-3000, TNC
- FG-7RS232CBL – RS-232 communication cable for torque testers and force gauges Shimpo FG-7000 series, TNC, TTC
- TTST-V-ADP – Upper adapter for mounting the TNC cap torque tester on the TTST-V test stand
- TNC-TP30 – Set of 4 clamping posts, 30 mm, for TNC torque testers
- TNC-TP40 – Set of 4 clamping posts, 40 mm, for TNC torque testers
- TNC-TP80 – Set of 4 clamping posts, 80 mm, for TNC torque testers
Documentation
- Brochure: family catalogue
- Data sheet / dimensions: tnc dimensions
- Document: declaration of conformity
- User manual: torque tester family user manual
Price and availability
Models without a listed price are offered in a configuration defined together with our technical support team: contact us for a quote stating your application and measuring range.
Selection guide: TNC
Shimpo TNC-2 digital bench-top cap torque tester for the opening and closing torque of caps, measuring range 0.1–2 N·m (0.89–17.7 in·lbf), accuracy ±0.3% of reading, samples from 19.5 to 190 mm, USB and RS-232 outputs.
Available models: TNC-2, TNC-5, TNC-10, TNC-20. Choose the measuring range so that the opening/closing torque of your caps falls in the middle part of the scale.
Guide to the series: TNC is the bench-top torque tester with adjustable clamping posts for bottles, flasks and jars (samples from 19.5 to 190 mm); TNP is the version with lower ranges and higher resolution for small closures; FG-7000TA is the portable model with an external sensor and adjustable clamp, for measurements outside the laboratory too.
Typical applications:
- Opening and closing torque of caps and closures
- Quality control in the pharmaceutical, medical and food industries
- Research and development
If in doubt, contact us: our technical support will recommend the model and capacity best suited to your application.
Integration and programming
From the menu you set the units (N·m, N·cm, in·lbf…), the measuring mode (track, peak, first peak, auto-peak, double peak) and the tolerance limits for an immediate pass/fail judgement. The USB and RS-232 outputs transfer the readings to the Shimpo software for statistics and reports; the internal memory allows in-line recording.
For repeatable laboratory tests, the TTST-V manual rotary test stand applies the torque in a controlled manner. Our technical team will help you define the test method.
Calibration and repair
Shimpo torque testers are supplied with a factory calibration certificate. Periodic verification is carried out with reference arms and masses or with a reference transducer; we recommend an annual interval or as required by your quality system. Clamping posts and clamps are available as spare parts.
Service: RODER S.r.l. – INNOVACHECK division handles calibration with certificate, periodic verification and repairs of Shimpo instruments in Italy. Contact us, stating the model and serial number.