Tramex CALBOXSMM5 calibration check box – for Skipper 5
- SKU: CALBOXSMM5
- VENDOR: TRAMEX
Couldn't load pickup availability
Safe and secure payments:
Informazioni di prodotto e di utilizzo
Calibration reference for the Skipper 5: by placing the instrument on the box you can check in a few seconds that the reading is within tolerance, before every survey. Recommended by Tramex for periodic checks.
Supplied: calibration check box only. The box has the same format as the CALBOXME5 but its calibration is specific to the Skipper 5. Extension handle, electrode protectors and pouch are separate accessories, available together in the AP-SMM5 pack.
Compatible with
What it is for
A survey report is only as good as the instrument that produced it: with the CALBOXSMM5 box, the surveyor can demonstrate that the Skipper 5 was under control at the time of measurement. Place the instrument on the box, read it and compare it with the reference; if the value is out of tolerance, the instrument should be sent for calibration. It does not replace the annual certified calibration.
How to use it
Switch the instrument on, select the scale indicated on the box, place the instrument on the box and compare the reading with the reference. No battery, no maintenance.
Features
| Compatibility | Skipper 5 (SMM5) |
|---|---|
| Function | Checking the reading against a known reference |
| Power supply | None |
| Code | CALBOXSMM5 |
| Included in | AP-SMM5 accessory set |
Technical data
| Function | On-site calibration check |
| Compatible instrument | Tramex Skipper 5 (SMM5) |
| Reference value, hardwood | 15.0% ±1.0% |
| Reference value, reduced depth | 16.0% ±2.0% |
| Reference value, fibreglass (GRP) | 20.0% ±2.0% |
| Product code | CALBOXSMM5 |
Documentation
Selection guide: CALBOXSMM5
Calibration check box specific to the Skipper 5: same format as the CALBOXME5, different calibration. It is the reference for periodic calibration checks on site: place the instrument on the box and in a few seconds you can verify that the reading is within tolerance. Compatible with Tramex Skipper 5 (SMM5). Recommended for those working under ISO 9001 or signing survey reports; it is also included in the AP accessory sets.
If in doubt, contact us: our technical support team will recommend the right accessory for your instrument and your application.
Integration
No configuration needed: switch the instrument on, select the scale shown on the box, place the instrument on it and compare the reading with the reference value. With the Tramex Meters app, the check can be recorded with date and time in the report.
Calibration and repair
The box has no batteries or wearing parts and does not require calibration; keep it in its pouch, away from moisture and heat sources. If the instrument's reading on the box is out of tolerance, the instrument must be sent for calibration: the box does not replace the annual certified calibration.
Service: RODER S.r.l. – INNOVACHECK division, Tramex distributor for Italy, will help you with selection, use and sending instruments to Tramex for certified calibration and repairs. Contact us stating the model and serial number of your instrument.