{"product_id":"tastatori-pneumatici-linearizzati-gtl222-tesa-1-5-mm-corsa-dell-asta-3-03230063","title":"GTL222 pneumatic linearised probes TESA, ± 1.5 mm, plunger travel 3.2 mm, radial cable","description":"\u003cp\u003e\u003cstrong\u003eTESA GTL 222-A inductive probe, measuring range ± 1.5 mm.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eDescription\u003c\/h2\u003e\u003cp\u003eGTL222-A pneumatic linearised probe, ± 1.5 mm, force = 0.2 N, radial cable.\u003c\/p\u003e\u003cp\u003eProbe:\u003c\/p\u003e\u003cp\u003e- Linearised probe\u003c\/p\u003e\u003cp\u003e- Measuring plunger mounted on a ball bearing\u003c\/p\u003e\u003cp\u003e- Guide ensuring low sensitivity to radial forces acting on the measuring plunger\u003c\/p\u003e\u003cp\u003e- Guide separate from the mounting shank, so that the movement of the measuring plunger is not adversely affected if the probe is clamped incorrectly\u003c\/p\u003e\u003cp\u003e- Ø 8 mm mounting shank that can be clamped along its entire length\u003c\/p\u003e\u003cp\u003e- Guides highly protected against the ingress of liquids (oils) or solids (dust) by a protective bellows\u003c\/p\u003e\u003cp\u003eMeasurement:\u003c\/p\u003e\u003cp\u003e- Probes intended for use with devices that integrate fully or semi-automated measuring sequences\u003c\/p\u003e\u003cp\u003e- Probe brought into the measuring position by pneumatic actuation\u003c\/p\u003e\u003cp\u003e- Contact points can be replaced or changed\u003c\/p\u003e\u003cp\u003e- Measuring force adjustable by changing the spring (depending on the model)\u003c\/p\u003e\u003cp\u003eTESA GTL 222-A inductive probe, compatible with the M4P-3 4-input interface with analogue output.\u003c\/p\u003e\u003cp\u003eTechnical data. Measuring range ± 1.5 mm; nominal output signal with M4P-3 100 mV for a travel of 100 µm from 0 with 1 V\/mm gain.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLinearised probe\u003c\/li\u003e\n\u003cli\u003eMeasuring plunger mounted on a ball bearing\u003c\/li\u003e\n\u003cli\u003eProbe brought into the measuring position by pneumatic actuation\u003c\/li\u003e\n\u003cli\u003eContact points can be replaced or changed\u003c\/li\u003e\n\u003cli\u003eMeasuring range ± 1.5 mm\u003c\/li\u003e\n\u003cli\u003eRepeatability limit 0.015 µm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eGTL222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eMeasuring range [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e± 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eRepeatability limit [µm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eHysteresis [µm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eMaximum permissible linearity error [µm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.2 + 2.4 x (L x L); 0.2 + 0.8 x L (with TESA interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003ePlunger lift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAdvance: pressure, lift: spring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eCable orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRadial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eSensitivity [mV\/V\/mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e73.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eCable length [m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eDIN 32876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMounting shank: nickel-plated; Measuring plunger: hardened steel; Protective bellows: Viton®; Ball contact point: carbide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMounting shank: Ø 8 mm; Contact thread: M2.5; Ball contact point: Ø 3 mm; Cable: 2 m; Connector: 5p DIN 45322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMoving mass: 6 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.02 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eCoefficient of linear expansion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.2 µm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.015 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e± 1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003ePlunger travel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e3.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e20 °C ± 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e73.75 mV\/V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003eMaximum permissible linearity error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eL in mm; 0.2 + 2.4 x (L x L) µm; 0.2 + 0.8 x L µm (with TESA interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eModels and variants\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\" align=\"left\"\u003eTESA code\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\" align=\"left\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\" align=\"left\"\u003eProtection rating\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\" align=\"left\"\u003eMeasuring force [N]\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\" align=\"left\"\u003eNominal pressure [bar]\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\" align=\"left\"\u003eMaximum pressure [bar]\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003e03230063\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePneumatic linearised GTL 222-A probe \/ Nominal measuring force 0.2 N\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIP50\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.25\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003e03290140\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eSet of 10 GTL 222 probes\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIP65\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1.2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.7\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003e03290171\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eSet of 10 GTL 222-A probes\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIP50\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.25\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cstrong\u003e03230054\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePneumatic linearised GTL 222 probe \/ Nominal measuring force 1.2 N\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIP65\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1.2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0.7\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eSupplied with\u003c\/h2\u003e\u003cp\u003eProbe · Clamping bush · Adjusting key · Inspection report · Instruction manual · Declaration of conformity\u003c\/p\u003e\u003ch2\u003eDocumentation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/6580\/2067\/files\/15-08-00-catalog_extract-dc_lever_probe_lever_probe_axial_probes.pdf?v=1794666283\" target=\"_blank\" rel=\"noopener\"\u003eDocument: 15-08-19-catalog extract-dc lever probe lever probe axial probes \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/6580\/2067\/files\/15-08-90-catalog_extract-numerical_index_index_3_cat_gen_en_p481.pdf?v=1794666088\" target=\"_blank\" rel=\"noopener\"\u003eDocument: 15-08-19-catalog extract-numerical index index 3 cat gen en p481\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/6580\/2067\/files\/15-08-19-catalog_extract-pneumatic_linearised_gtl222_probes_1_5_m.pdf?v=1794666820\" target=\"_blank\" rel=\"noopener\"\u003eDocument: 15-08-19-catalog extract-pneumatic linearised gtl222 probes 1 5 m\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/6580\/2067\/files\/15-08-19-datasheet-03200422b.pdf?v=1794666825\" target=\"_blank\" rel=\"noopener\"\u003eData sheet \/ dimensions: 03200422b\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/6580\/2067\/files\/12-02-08-datasheet-03200393a.pdf?v=1794666831\" target=\"_blank\" rel=\"noopener\"\u003eData sheet \/ dimensions: 03200393a\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eManufacturer's official page: \u003ca href=\"https:\/\/tesatechnology.com\/it\/products\/1d-probes\/standard-axial-probes\/2e30df0e-32cc-49c0-ad9d-97526ec89a22\" target=\"_blank\" rel=\"noopener nofollow\"\u003etesatechnology.com\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003ePrice and availability\u003c\/h2\u003e\u003cp\u003eProducts without a listed price are offered with a configuration defined together with our technical support: \u003cstrong\u003econtact us for a quote\u003c\/strong\u003e stating the model, quantity and application.\u003c\/p\u003e","brand":"TESA","offers":[{"title":"03230063 – Pneumatic-lift probe GTL 222-A linearised \/ Nominal measuring force 0.2 N","offer_id":55921611702611,"sku":"03230063","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"03290140 – Set of 10 probes GTL 222","offer_id":55921616421203,"sku":"03290140","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"03290171 – Set of 10 probes GTL 222-A","offer_id":55921616453971,"sku":"03290171","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"03230054 – Pneumatic-lift probe GTL 222 linearised \/ Nominal measuring force 1.2 N","offer_id":55921616486739,"sku":"03230054","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/6580\/2067\/files\/15-08-19-main.webp?v=1794666837","url":"https:\/\/innovacheck.shop\/en\/products\/tastatori-pneumatici-linearizzati-gtl222-tesa-1-5-mm-corsa-dell-asta-3-03230063","provider":"RODER SRL - INNOVACHECK SHOP","version":"1.0","type":"link"}